Air Cooled Chillers: Types, Applications and Principles - IQS Directory

Author: Mirabella

Jul. 28, 2025

Air Cooled Chillers: Types, Applications and Principles - IQS Directory

Air Cooled Chillers: Types, Applications and Principles

Chapter 1: Understanding the Functionality of Air-Cooled Chillers

This chapter provides an introduction to the fundamentals of air-cooled chillers, discussing their essential components and functional mechanisms.

If you are looking for more details, kindly visit Huateng.

What Exactly Are Air-Cooled Chillers?

Air-cooled chillers are a type of refrigeration system used to lower the temperature of fluids, working alongside a building’s air handling system. Unlike the conventional industrial chillers that require cooling towers, these chillers expel heat outside by utilizing fans. By using air to cool water and other fluids, they effectively reduce the temperatures of equipment, processes, and spaces by absorbing heat and dissipating it efficiently.


Comprising a compressor, evaporator, condenser, and expansion valve, air-cooled industrial chillers are employed in diverse environments including large industrial operations, shopping malls, industrial complexes, hotels, and medical facilities. These chillers are also ideal for locations with several buildings such as amusement parks and outdoor shopping centers, delivering reliable cooling solutions for both substantial and smaller operations.

Their compact build renders them portable, cost-effective for maintenance, and easy to install. Versatile portable air-cooled chillers are practical for large-scale events or urgent situations, resembling the simpler structure of water-cooled chillers. Most air-cooled chillers feature either screw compressors or scroll compressors.


Often known as modular chillers, air-cooled chiller units can be stacked horizontally to boost cooling capabilities, ranging from approximately 10 refrigeration tons (RT) to 550 RT. A single air-cooled chiller with scroll compressors can reach a maximum capacity of about 200 RT, while those equipped with screw compressors can hit up to 550 RT.

These units typically incorporate at least two compressors for added reliability. Should one compressor experience a malfunction, the other maintains operation, although cooling strength is lowered to 50%. Air-cooled chillers offer lower efficiency levels than their water-cooled counterparts, with an energy efficiency ratio near 1.00 kW/ton, as opposed to the enhanced efficiency observed in water-cooled chillers.

Key Components of an Air-Cooled Industrial Chiller

The key elements of an air-cooled chiller include:

Compressor of an Air-Cooled Industrial Chiller

The compressor drives the refrigerant flow within the chiller. Compressor types include screw, reciprocating, scroll, rotary, and centrifugal. Centrifugal compressors are particularly dynamic, operating differently by using an impeller to accelerate and then slowly reduce the speed of the gas to compress it, contrasting with positive displacement compressors that condense gas using mechanisms such as screws, pistons, or rotors to elevate vapor pressure.


Ideal for high-capacity uses, compressors come in three forms: hermetic, semi-hermetic, and open. In hermetic compressors, both the compressor and electric motor are encased in a hermetically sealed enclosure, typically serving low-capacity needs. Semi-hermetic compressors feature a two-part casing, allowing mid-range capacitancy, with the electric motor and compressor sharing an enclosure. Open compressors, with separated but coupled motor and compressor units, suit high-capacity applications.

Condenser of Air-Cooled Industrial Chillers

This component functions as a heat exchanger, transferring heat from refrigerant to air, utilizing copper tubes with liquid refrigerant and aluminum fins to promote heat exchange. Hid efficient air-cooled chillers usually employ air-cooled condensers, while others can be evaporative or water-cooled.


In water-cooled versions, water facilitates refrigerant cooling, unlike evaporative condensers that blend both air and water to raise air temperature through water evaporation. Air aids this process by facilitating vapor removal.

Fans of the Air-Cooled Industrial Chiller Condenser

The defining feature of air-cooled chillers, these fans circulate air across the condenser, extracting heat and allowing the system to restart the cooling cycle effectively.


Expansion Valves of Air-Cooled Industrial Chillers

The expansion valve finely controls refrigerant flow based on cooling load variations. By receiving and depressurizing liquid refrigerant before it enters the evaporator, it creates a backflow and transforms refrigerant into a low-pressure liquid and vapor mixture, eventually turning it into hot then cold gas as pressure rises.

Seven expansion valve types exist—thermal, low-pressure, high-pressure, electronic, and automatic, among others—each regulating refrigerant flow and helping maintain the pressure difference between condenser and evaporator while enabling refrigerant transformation inside.


Evaporator or Heat Exchanger of an Air-Cooled Chiller

The evaporator extracts heat from the refrigerant before it goes back to the condenser. It's a heat exchanger moving heat from refrigerant to water or coolant. Evaporator types include coil, shell and tube, and plate, defined by efficiency in heat transfer.


By cooling the refrigerant to gas, the evaporator allows it to absorb heat from water or air handling units. Evaporator modifications, like shell and tube, finned, and plate, aid distinct cooling applications by fostering greater contact area for efficient heat transfer.


Notably, evaporators vary in design—

  1. Shell and Tube: Typically comprising copper or steel tubes, ideal for liquid cooling.
  2. Finned Evaporators: Feature secondary fins enhancing heat exchange, improving air cooling efficiency through increased surface exposure.
  3. Plate Evaporators: Utilize grooved metal plates for refrigerant distribution. Variations include welded metal plates encasing a tube, utilizing eutectic solutions for enhanced contact.

Filter Drier of Air-Cooled Industrial Chillers

This part protects the system by removing impurities and moisture. Due to clogging from extended use, replacing the filter drier periodically is necessary to ensure system longevity and efficiency.

Chapter 2: How Air Cooled Industrial Chillers Work?

The operational concept of air-cooled industrial chillers revolves around extracting heat from processed water within a closed-loop chilling system. These refrigeration units are essential in process cooling applications for manufacturing, plastics, food and beverage, and HVAC systems. After the chilled water circulates through the facility's air handler or process equipment, it absorbs heat and returns to the chiller. Inside the chiller’s evaporator, efficient heat exchange occurs as the liquid refrigerant absorbs the unwanted thermal energy from the water. The refrigerant evaporates over the evaporator tube bundle, turning into a low-pressure vapor.


This low-pressure refrigerant gas then travels to the compressor, where it is compressed into a high-pressure, high-temperature vapor. Next, the refrigerant moves into the air-cooled condenser coils. Here, condenser fans force ambient air across the coils, rapidly dissipating heat and condensing the refrigerant gas back into a high-pressure liquid. Installing air-cooled chillers outdoors or in a well-ventilated indoor area helps eliminate excess heat buildup, making them ideal for environments where water use is limited or not feasible.

Once heat is released from the chiller by the condenser fans, the now high-pressure liquid refrigerant is directed through an expansion valve. This valve regulates flow and reduces the refrigerant’s pressure and temperature, transforming it into a low-pressure liquid. As a continuous cycle chilling process, this cooled refrigerant returns to the evaporator, where it begins absorbing heat again. This ongoing cycle provides reliable cooling for critical equipment, industrial processes, and climate control solutions.

Modern air-cooled chiller systems offer features such as microprocessor controls, variable speed compressors, energy-efficient EC fans, and environmentally friendly refrigerants for optimized performance, energy savings, and compliance with current industrial refrigerant regulations.

Air Cooled Industrial Chillers vs. Water Cooled Industrial Chillers

Air-cooled chillers and water-cooled industrial chillers are both types of vapor compression systems commonly used to provide process cooling and commercial air conditioning. Both utilize mechanical compressors (such as scroll, screw, or centrifugal compressors) to circulate refrigerant throughout the chiller system, but the primary difference lies in how each rejects heat from the refrigeration cycle.


In water-cooled chiller systems, water is circulated through a sealed condenser and then flows to a cooling tower, where the process water is cooled via evaporation. This requires additional infrastructure, including cooling towers, condenser water pumps, and treatment systems. In contrast, air-cooled chillers use powerful condenser fans to force outdoor (or facility) air over the condenser coils, eliminating the need for a cooling tower. Because air-cooled models do not require extra water system components, they offer a more compact design, easier installation, lower upfront investment, and reduced long-term maintenance costs—making them a popular choice for many industrial, institutional, and commercial cooling applications.

While water-cooled chillers may offer higher efficiency in extremely large or hot applications, they incur extra maintenance costs and require regular water treatment. Air-cooled chillers are valued for their lower operating costs, ease of maintenance, and reliable operation in fluctuating climates. When comparing chiller technologies, consider total cost of ownership, installation requirements, energy efficiency ratios (EER), seasonal performance, and local water resource availability.

Factors to Consider When Choosing an Air Cooled Chiller

When selecting an air-cooled chiller or industrial cooling system for your facility, several key factors can impact operational efficiency, energy consumption, and system longevity:

Minimum Industrial Chiller Capacity

Evaluate your process’s peak thermal load and consider environmental conditions when sizing an air-cooled industrial chiller. Air-cooled chillers are well-suited for cooler climates with significant day-night or seasonal temperature swings. Ensure the unit’s cooling capacity (measured in tons or kilowatts) meets your specific process or HVAC demands. For equipment or applications with moderate cooling loads, air-cooled chillers offer a flexible and energy-efficient solution.

Effect of Industrial Chiller Height

Altitude plays a critical role in an air-cooled chiller’s cooling capacity. At higher elevations, thinner air means reduced heat rejection efficiency, which can decrease overall system performance. Manufacturers provide derating guidelines to adjust for high-altitude applications in industrial and commercial environments.

Industrial Chiller Control Type

The choice of control system can dramatically influence energy efficiency and remote monitoring capabilities. Advanced chillers are equipped with digital or microprocessor-based controls for enhanced precision, alarm notifications, and integration into building management systems (BMS).

Industrial Chiller and Refrigerant Pressure

Industrial chillers are engineered to safely manage high refrigerant pressures. Select units with proven safety mechanisms and high-quality heat exchangers. Employing lower-pressure, environmentally friendly refrigerants (such as R410a, R134a, or next-generation HFO blends) can improve performance and reduce compliance costs with environmental regulations.

Resistance to Air Temperature

Ambient temperature significantly affects chiller efficiency and compressor energy use. For every 1°C rise in ambient temperature, air-cooled chiller capacity can decline by approximately 1%. Consider units with oversized condensers, variable-speed fans, and hot weather optimization if your operation is in a warm climate or exposed installation.

Evaporator Pressure Drop Value

Minimize evaporator pressure drop to maximize system efficiency and reduce energy costs. Specify chillers with large-diameter or enhanced-surface evaporator designs for lower fluid friction losses, ensuring a stable and efficient cooling process.

Physical Size of an Industrial Chiller

Compact footprint is a major advantage of air-cooled chillers, which facilitates installation in dense or space-limited facilities. Make sure to confirm clearance for air flow and maintenance access during system design.

The Amount of Noise Produced by the Device

Operating noise is a significant factor for many industrial settings. Look for air-cooled chiller models engineered with low-noise fans, sound attenuating enclosures, and vibration isolation. For noise-sensitive environments, select models with guaranteed sound pressure levels below 75 dBA at 16.4 feet (5 meters).

Number of Compressors

Multiple compressor configurations provide redundancy and staged capacity control, optimizing performance under variable load conditions. Review the technical specifications to match the number of compressors to your reliability and energy efficiency goals.

Additional Considerations:

  • Energy Efficiency Ratio (EER) and Coefficient of Performance (COP): Prioritize air-cooled chillers with high EER or COP ratings to minimize electricity consumption and operational expenses.
  • Industry Certifications and Compliance: Ensure your chiller meets relevant standards such as AHRI, CE, UL, or ISO certifications for industrial refrigeration systems.
  • Maintenance Requirements: Evaluate the ease of service, accessibility of key components, and availability of after-sale support from the manufacturer or distributor.
  • Warranty and Service Agreements: Thoroughly review warranty terms and consider extended service agreements for critical installations.

Leading Manufacturers and Suppliers

Chapter 3: What are the types of air-cooled industrial chillers?

Air-cooled industrial chillers are essential components in process cooling and HVAC systems across a range of industries. These chiller systems are categorized by the type of compressor utilized, which include screw, reciprocating, scroll, rotary, and centrifugal compressors. Understanding the various types of air-cooled chillers ensures optimal selection for specific industrial cooling applications, maximizing energy efficiency, cooling performance, and system reliability.

Portable Air Cooled Industrial Chiller

The term "portable air cooled industrial chiller" refers to the system's standard configuration, rather than the ability to move the unit. In reality, once installed, most portable air cooled industrial chiller units are stationary and not intended for frequent relocation. This designation describes any packaged chiller system that integrates all necessary components—including the refrigeration circuit, circulating pump(s), and water reservoir—within a compact cabinet.


These air-cooled chillers are designed for plug-and-play installation, enabling fast setup for industrial process cooling, manufacturing, laboratory, or medical applications. The built-in chiller controls typically feature motor starters with a single-point electrical connection for streamlined installation. Advanced controllers on modern air cooled chillers provide automated maintenance reminders, diagnostic fault codes, technical alarms, and system alerts to minimize unplanned downtime and extend operation life. Portable chillers are available in a variety of cooling capacities, ranging from 2 to 100 tons, meeting the needs of both small and large-scale facilities.

Portable Air Cooled Industrial Chiller Standard Flow

The standard flow chiller system comes equipped with an integrated water tank. It operates within a closed-loop process cooling arrangement, where chilled water is pumped from the chiller, circulates through the equipment or heat exchanger, and returns to the unit under pump pressure, ensuring consistent coolant temperature and stable chilled water supply.

Portable Air Cooled Industrial Chiller Reversal Flow

The reverse flow air-cooled industrial chiller lacks an on-board tank, instead utilizing an open-loop cooling design. With this configuration, the chiller relies on an externally situated tank or trough. Water gravity-feeds from the external reservoir to the chiller's pump, passes through the evaporator and filtration system, and is redirected back to the reservoir, making it ideal for process cooling where direct fluid recirculation is required.

Portable Air Cooled Industrial Chiller Continuous Flow

Continuous flow portable industrial chiller units are engineered for high-throughput operations that require fluid temperature control in a single pass. These systems incorporate a dedicated pump, integrated tank, and secondary heat exchanger, followed by an inline filter, ensuring precise temperature management and contamination control even under demanding industrial load profiles.

Industrial Stationary Air Cooled Chillers

Industrial stationary air cooled chillers, also called modular chiller systems, are designed for permanent installation and large commercial or industrial environments. A "stationary air cooled industrial chiller" typically does not include an integrated pump or water tank. Instead, these chillers operate as central cooling modules, connected to external pumps and reservoirs via engineered piping networks.

If you are looking for more details, kindly visit Modular Air Cooled Chiller.


Each major component—chiller, pump, and reservoir—requires dedicated electrical connections and precise controls. Correct sequencing and wiring of electrical controls are critical, ensuring the chiller does not initiate the refrigerant cycle until pumped circulation is established. Stationary air cooled chillers are available in cooling capacities from 2 tons up to 200 tons, making them suitable for large-scale process cooling, industrial HVAC, plastics manufacturing, chemical processing, and other demanding chilled water applications.

Reciprocating Industrial Chiller

Reciprocating industrial chillers utilize piston compressor technology to compress refrigerant gas. The reciprocating piston design applies incremental pressure to the gas, raising its temperature for heat exchange. Adjustable intake and exhaust valves orchestrate piston cycles, and advanced systems disengage pistons in response to part-load cooling requirements, delivering high adaptability to fluctuating heat loads. For precise temperature control, some reciprocating industrial chiller systems use a combination of hot-gas bypass and digital capacity control to match refrigeration output with user demand, though hot-gas bypass can reduce energy efficiency compared to more modern control strategies.


Reliable operation depends on correct electrical setup of each component. Reciprocating chillers are commonly used in smaller industrial facilities and laboratories, with models available from 2 to 200 tons cooling capacity. These chillers excel in process cooling where intermittent or variable workloads are present.

Rotary Screw Industrial Chillers

Rotary screw industrial chillers employ helical (screw-type) compressor technology for continuous, energy-efficient operation. The compressor features interlocking rotors inside a precision housing, reducing refrigerant volume through direct mechanical action as the helical rotors spin. This design minimizes vibration and maintenance requirements, resulting in reliable industrial refrigeration for large-scale operations.


Screw compressor chillers are favored for their robust performance and low noise characteristics. The cooling capacity of a rotary screw compressor ranges from 20 tons up to 450 tons, serving extensive industrial, commercial, and institutional applications. Capacity control is achieved using a sliding inlet valve or variable speed drive (VSD/VFD), enabling precise modulation according to real-time process or building cooling demands—an important factor for energy savings and sustainability goals.

Centrifugal Compression Industrial Chillers

Centrifugal compression industrial chillers leverage high-speed impellers—much like those in a centrifugal pump—to compress refrigerant efficiently. This design translates to a compact physical footprint and exceptional cooling capacities, making centrifugal chillers popular in large commercial buildings, district cooling plants, and heavy-industrial environments that require bulk chilled water supply.


Modern centrifugal industrial chillers incorporate energy-saving technologies such as variable speed drives (VSDs) and adjustable inlet guide vanes to optimize cooling performance under part-load conditions, reduce energy costs, and minimize system wear. With capacities often starting at 150 tons and scaling much higher, these chillers deliver high-efficiency cooling for a wide variety of mission-critical environments.

Frictionless Centrifugal Industrial Chillers

Frictionless centrifugal industrial chillers represent the state-of-the-art in oil-free chiller design. Similar in operation to standard centrifugal chillers, they are distinguished by the use of magnetic bearings, which eliminate mechanical friction and the need for lubrication. This results in ultra-quiet operation, reduced maintenance, and enhanced energy efficiency—key advantages in data centers, hospitals, and manufacturing facilities with sensitive environmental controls.


These chillers incorporate high-efficiency, variable-speed direct drive (DC) motors for precise energy management. Frictionless centrifugal chiller systems are available in capacities from 60 tons to 300 tons, catering to end-users requiring superior reliability, quiet operation, and maximum energy savings.

Absorption Industrial Chillers

Unlike mechanical compressor-based chillers, absorption industrial chillers deliver cooling using a thermally driven refrigeration process powered by waste heat, steam, or natural gas. This technology is preferred in facilities where reducing electrical demand is a priority, or where waste heat is readily available, such as combined heat and power (CHP) plants and large manufacturing complexes. Two working fluids, most commonly lithium bromide as the absorbent and water as the refrigerant, interact through carefully controlled cycles to provide chilled water for air conditioning or process cooling needs.


The absorption refrigeration cycle starts by using thermal energy to drive off water vapor from the absorbent solution. The refrigerant vapor is then condensed to release heat before being routed to the low-pressure evaporator, where rapid vaporization absorbs heat from the chilled water circuit. The process results in efficient cooling with minimal electrical input, making absorption chillers environmentally friendly options with low greenhouse gas emissions. These systems are especially attractive for sites seeking sustainability certifications or for applications with variable energy sources.

When evaluating which air-cooled industrial chiller is best for your facility, consider critical factors such as cooling load requirements, available energy sources, installation space, maintenance preferences, and integration with existing cooling or process infrastructure. Industrial chiller manufacturers and suppliers can help with system sizing, application engineering, and life-cycle cost analysis to ensure you select the optimal chiller technology for your specific needs.

Chapter 4: AWhat are the applications and benefits associated with air-cooled industrial chillers?

This chapter will explore the applications and advantages of air-cooled chillers.

Applications of Air Cooled Industrial Chillers

For industrial operations, air cooled chillers are used to create heat through the use of friction, high-powered equipment, and furnaces or ovens. They are able to increase the lifespan of heavy-duty equipment by circulating cooled liquid through equipment to maintain their efficiency and productivity. Due to the fact that the food industry has strict regulations regarding the storage temperatures of ingredients and products, air cooled industrial chillers are used as a traditional cooling system for food. In the pharmaceutical field, medicines require using chilled water in the manufacturing process and precise temperature control. Industrial chiller systems have the accuracy and precision for the chilling process and can be central process chillers or compact process chillers.


Common types of pharmaceutical chillers include reciprocating, centrifugal, and absorption units. In power generation, power plants generate significant heat during electrical power production. Chillers are employed to cool components and processes by absorbing the generated heat. Medical instruments, such as CT scanners, MRI scanners, and LINAC machines, require precise temperature control to manage the heat they produce. Air-cooled chillers are utilized to maintain consistently cool temperatures, ensuring the efficient operation of critical equipment.


Benefits of Air Cooled Industrial Chillers

Air cooled chillers can be quickly integrated into existing systems, saving both time and money during installation. Their simpler setup compared to water cooled systems means installation teams require less time, resulting in significant upfront cost savings. Another advantage of air cooled chillers is their reduced number of components to maintain compared to water cooled systems. They do not require a condenser pump, cooling tower, or other complex parts, thereby lowering maintenance needs. Air cooled chillers are particularly beneficial in areas prone to drought or with limited water supply, offering a water-saving alternative to traditional systems. By using ambient air instead of water for cooling, air cooled chillers eliminate the need for water, optimizing performance. Additionally, air cooling systems do not alter ambient humidity or temperature as significantly as other chiller systems.

Drawbacks of Air Cooled Industrial Chillers

Air cooled chillers may have a shortened lifespan due to their outdoor location, exposing them to environmental elements such as ice, rain, snow, wind, and hail. Additionally, air cooled chillers tend to produce higher levels of noise because of the cooling fans.

Conclusion

  • Air cooled industrial chillers are refrigeration systems that cool fluids and work in tandem with the air handler system of a facility.
  • Air cooled industrial chillers are types of industrial chillers that rely on the use of fans to reject heat outside the building rather than relying on cooling towers and have four major parts, which are a compressor, an evaporator, a condenser, and an expansion valve.
  • Air cooled industrial chillers can be found in various types, which include portable air cooled chillers and industrial stationary air cooled chillers.
  • The working principle of air cooled industrial chillers is based on the absorption of heat from processed water. Once the air handler system uses up the water, it becomes warm and is returned to the chiller. The chiller’s evaporator is utilized to transfer heat away from the water.

Modular chiller plants: when are they the right choice? - ARANER

In the current context where energy efficiency is crucial, the choice between conventional and modular chiller plants stands at a crucial crossroads. 

As we’ll see below in the article, the modular chiller system offers numerous advantages in a number of circumstances. 

Such is the case of the industries that are part of the green transition, such as renewable energy production or electric vehicle manufacturing.  As such, modular chillers for battery production factories have been hailed as a crucial solution as the development of electric vehicles continues.

By providing efficient yet flexible and precise cooling, a modular chiller plant can have an impact on reducing the environmental impact of cooling while bringing in cost reductions.

This is partly why the modular chillers market has experienced a noticeable growth, a trend that is expected to continue. For instance, GrandView Research foresees a compound annual growth rate (CAGR) of 6.8% from to for these systems’ market value, building from a value at USD 2.42 billion in . The consultancy firm considers the increasing awareness regarding sustainability in cooling as a major force driving this growth. On the other hand, Expert Market Research highlights the growing importance of water-cooled modular chillers over air-cooled systems for the foreseeable future.

But what exactly are modular chiller plants and when are they the best choice for cooling projects? Keep reading to find out. 

What are modular chiller plants?

Modular chillers are cooling systems that consist of multiple independent chiller units designed to work efficiently together. As such, the modular chiller plant departs from the conventional model that relies on having a single large chiller unit.

The fact that these chiller units can be arranged in a modular configuration allows for flexibility in design and crucial scalability. This capacity is precisely the main advantage of modular chillers: as cooling demands change or grow, additional modules can be added to the system to increase capacity. Conversely, if cooling requirements decrease, modules can be removed or turned off to save energy.

The result is a versatile and efficient solution for cooling that is an adequate choice for a wide range of applications.

Air-cooled and modular water cooled chillers are available today. There are also other adaptations, including different tonnage options. However, all of them rely on the same basic set of components, including compressors, pumping and control systems. Modular chillers are prewired and many present integrated cooling towers, fans, boilers, and generators.

What are the benefits of modular chillers

1. Increased redundancy

With modular chillers, one module failing doesn’t necessarily mean downtime: when one module fails, the rest of the system can continue operating while losing a small percentage of the overall plant capacity.

2. Precision

Modular chillers can be designed so that only the necessary cooling capacity is deployed at the time and place when they’re needed. While this brings in another additional benefit, one of their key advantages is to provide precise and stable temperature control within a narrow range. 

In fact, their zoning capacities mean that independent temperature control is possible, all with a fast response time.

3. Energy efficiency

The modular chiller system can be optimized for varying loads, which leads to improved efficiency compared to fixed-capacity units.

4. Flexibility

Modular chillers can be adjusted to fit the specific needs of a facility, and scaled with additional modules as needed. Their flexibility also means modular chillers can be adapted for industrial heat pumps, thus bringing in both heating and cooling capacities.

5. Easy maintenance

Thanks to their smaller components, modular chillers are typically easier to maintain and repair.

6. Space efficiency 

While traditional large chiller systems often require dedicated rooms or outdoor space for installation, modular chiller plants offer a more compact footprint. The options are many, and include their installation in smaller spaces or their distribution throughout a facility.

7. Short installation time

Commissioning times are greatly reduced, as all piping joints, electrical and control signals are tested at the factory. Additionally, because modular plants come from the factory as standard equipment, the number of required permits is greatly reduced.

8. Factory-made means higher quality

Works like pipe cutting, welding and cable pulling are performed at the factory in a controlled and clean environment, with tools for precision. This translates into excellent quality for the final product, as opposed to the conventional approaches, which means site works are done in a dirty and sometimes unsuitable environment.

Additionally, the fact that most materials are installed at the factory and the site works means required site manpower is reduced. In conventional chiller plants, a wide range of materials and qualified manpower is required, which sometimes might not be available (for instance, in the case of remote areas). Modular chiller plants solve this.

9. Noise control

While conventional facilities can pose noise pollution, a modular chiller plant offers reduced noise levels.

When are modular chillerplants convenient?

Based on the previous advantages, here are some scenarios where modular chillers would be the preferred option:

  • When precise temperature control is needed for safety and quality. Such is the case of the manufacturing of certain products, including battery production factories.
  • Sites aiming at flexible and scalable cooling solutions. For instance, certain data center cooling solutions need to face fluctuating cooling demands due to changes in server loads and equipment upgrades. On the contrary, a modular chiller system can efficiently adapt to these varying loads, providing reliable and energy-efficient cooling while allowing for future expansion.
  • Projects that demand a quick installation 
  • Projects that have limited access to manpower
  • Sites where space limitations are crucial
  • Operators looking to minimize their environmental impact. This is particularly true of industries that are part of the transition towards a green economy, including renewable energy production facilities, waste-to-energy plants or water treatment and desalination plants

While modular chillers offer a wide range of advantages, they aren’t the only option and certainly not the best option for all types of projects. 

This is why at ARANER we prefer offering a tailor-made approach to cooling solutions, recognising a ‘one-size-fits-all-’ mentality is not the best approach to thermal engineering.

Our aim is to design plants to meet project demands, all with the smallest environmental footprint and best cost-efficiency. This often involves a customized approach to cooling plants that may involve state-of-the-art solutions like  Thermal Energy Storage (TES) to boost efficiency.

As such, when approached with a new project, we take the time to analyze which solution will optimize the plant’s energy and economic output. Our thermal engineering expertise guides your project in the choice between modular and conventional chillers, leading to cutting-edge installations that adjust to each project’s needs and guarantee total reliability and top-performance. 

If you want to learn more, please visit our website Brine Chiller Units.

23

0

Comments

0/2000

All Comments (0)

Guest Posts

If you are interested in sending in a Guest Blogger Submission,welcome to write for us!

Your Name (required)

Your Email (required)

Subject

Your Message (required)

0/2000